Rating | 125 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 12 AWG - 1000 kcmil stranded, tinned copper, nickel coated copper, or silver coated copper. |
|
Insulation | Extruded SR |
| Conductor size | Minimum average thickness | Minimum thickness
at any point |
| 10-12 AWG | 30 mils | 27 mils |
| 8-2 AWG | 45 mils | 40 mils |
| 1-4/0 AWG | 50 mils | 45 mils |
| 250-500 kcmil | 65 mils 58 mils |
| 501-1000 kcmil | 80 mils | 72 mils |
|
Jacket | Extruded XLPO |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 10-2 AWG | 15 mils | 12 mils |
| 1-4/0 AWG | 20 mils | 16 mils |
| 250-500 kcmil | 30 mils | 24 mils |
| 501-1000 kcmil | 40 mils | 32 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances. |
|