APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3452 Issued:1982-04-14
Revised:2012-07-12
Style 3452 Single Conductor with Extruded Insulation

Rating125 deg C, 30 Vac, VW-1 Flame.
Conductor40 AWG min. material not specified.
InsulationExtruded Solid or Foamed XLPE, 4 mils min. at any point, 100 mils maximum.
AssemblyInsulated conductor is built with inner covering, outer conductor, middle covering, and outer covering.
Inner CoveringOptional - 2 mils minimum at any point Extruded XLPE or Non-Extruded Lacquered Braid.
Outer ConductorOptional - Non-Ferrous Metallic Braid or Wrap. A wrap of Conductoraluminum faced Mylar tape with an uninsulated drain wire(s) may be used when the optional outer covering is used.
Middle CoveringOptional - 2 mils minimum at any point Extruded XLPE or Non-Extruded Lacquered Braid.
ShieldOptional.
Outer CoveringOptional - XLPE 12.5 mils min. at any point, 40 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Low Energy Non-Hazardous Circuits in Audio and Video Equipment.