APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3459 Issued:1982-12-02
Revised:2012-10-31
Style 3459 Single conductor with extruded insulation

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, solid or stranded.
InsulationExtruded PE, XLPE, Foamed PE or Foamed XLPE, 3 mils minimum thickness at any point, 100 mils maximum thickness.
ShieldOptional.
Inner CoveringExtruded PVC, Nylon, TPE, FEP, PVDF, ETFE, XLPE, FRPE or lacquered braids, 2 mils minimum thickness at any point.
ShieldOptional.
Outer CoveringOptional over braided metal shield, otherwise, Extruded PVC, Nylon, FEP, PVDF, ETFE or lacquered braids, 2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment in Class 2 Circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024