APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3466 Issued:1983-01-03
Revised:2012-04-23
Style 3466 Single conductor with extruded insulation.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded.
InsulationExtruded XLPVC, Inner layer - 10 mils minimum average thickness, 9 mils minimum thickness at any point; Outer layer - Irradiated PVC, 15 mils min average, 13 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseDoubly protected internal wiring for use in television receivers and video products, or internal wiring of appliances and electronic equipment.