Rating | 200 deg C, 7500 Vac, Horizontal flame. |
|
Conductor | 22 AWG - 12 AWG, nickel, nickel plated copper, tin plated copper, or nickel plated iron. If tinned copper strands are used, they shall be No. 26 or larger. |
|
Insulation | Extruded SR, 30 mils minimum average thickness, 27 mils minimum thickness at any point. |
|
Covering | Fiberglass braid. |
|
Braid | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Electronic Ignition or similar application in Gas Ranges or Gas or Fuel Oil Burner Systems where protected from damage during handling, installation and servicing of the appliance. |
|