| Rating | 200 deg C, 7500 Vac, Horizontal flame. |
|
| Conductor | 22 AWG - 12 AWG, nickel, nickel plated copper, tin plated copper, or nickel plated iron. If tinned copper strands are used, they shall be No. 26 or larger. |
|
| Insulation | Extruded SR, 30 mils minimum average thickness, 27 mils minimum thickness at any point. |
|
| Covering | Fiberglass braid. |
|
| Braid | Optional. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Electronic Ignition or similar application in Gas Ranges or Gas or Fuel Oil Burner Systems where protected from damage during handling, installation and servicing of the appliance. |
|