APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3483 Issued:1984-04-20
Revised:2012-05-08
Style 3483 Single Conductor with Extruded Insulation and Extruded or Non-Extruded Jacket

Rating90 deg C, 30 Vac, Horizontal Flame.
Conductor40 AWG min, material not specified.
InsulationExtruded ETFE or Extruded FRPE or Extruded XLPE or Extruded PVC, Solid or Foamed, 3.0 mils minimum at any point, 100 mils max.
ShieldOptional.
CoveringOptional - Non-Extruded Polyester or Polyamide Tape, 0.2 mil minimum at any point applied with 50 percent overlap and heat sealed.
JacketExtruded ETFE or Extruded FEP or Extruded PFA or Extruded PVC, minimum wall at any point 4 mils; or spirally wrapped Non-Extruded PVC, Non-Extruded ETFE, Non-Extruded FEP or Non-Extruded PFA Tape applied with 50 percent overlap as a first layer and spirally wrapped 0.2 mil Non-Extruded Polyester or Polyamide Tape applied with 50 percent overlap and heat sealed as a second layer. Minimum wall at any point 2 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.