APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3499 Issued:1986-04-28
Revised:2011-10-26
Style 3499 Insulated Wire

Rating150 deg C, 7500 Vac, Horizontal flame.
ConductorNo. 8 AWG - 600 kcmil solid or stranded.
InsulationEPDM, 125 mils min average, 112 mils minimum at any point. See facing page for compound designation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring Appliances, where no flexing occurs, either after installation or during servicing.