APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3504 Issued:1986-08-25
Revised:2011-10-19
Style 3504 Single conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 14 AWG solid or stranded, tinned, bare or silver plated copper; or solid or stranded coated high strength copper - min. 90% conductivity.
InsulationExtruded XLPVC, 10 mils min average thickness, 8 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded XLPVC, 10 mils min average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances where not exposed to mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2024