APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3512 Issued:1987-08-18
Revised:2019-10-11
Style 3512 Single Conductor with Extruded Insulation.

Rating200 deg C, 600 Vac, Horizontal Flame.
Conductor0.3 - 250 sq mm, solid or stranded. If tinned copper strands are used, they shall be 0.0152 in diameter or larger.
SeparatorOptional.
InsulationExtruded SR.
Conductor sizeMinimum average thicknessMinimum thickness at any point
0.3-4.0 sq mm30 mils27 mils
4.1-9.0 sq mm45 mils40 mils
9.1-35.0 sq mm60 mils54 mils
35.1-100.0 sq mm80 mils76 mils
100.1-250.0 sq mm95 mils85 mils
Maybe applied in two layers with an intermediate glass braid (optional).
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances where totally enclosed.

UL and the UL Logo are trademarks of UL LLC © 2024