APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3522 Issued:1989-04-11
Revised:2012-04-09
Style 3522 Multiple-conductor cable using non-integral jacket.

Rating150 deg C, 300 Vac, Horizontal flame.
InsulationLabeled Style 3068, 18 or 16 AWG only.
AssemblyTwo singles laid parallel with an overall Jacket.
JacketExtruded SR, 23 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSupply Leads for Fixtures where not subject to mechanical abuse, and where the acceptability of the combination is determined by Underwriters Laboratories Inc.