Rating | 125 deg C, 30 Vac, Horizontal Flame. |
|
Conductor | 40 AWG minimum, Solid or Stranded Round. |
|
Insulation | Extruded PFA, extruded FEP or extruded ETFE, 3 mils minimum at any point, 40 mils maximum. |
|
Shield | Optional. |
|
Jacket | Extruded PFA, extruded FEP or extruded ETFE, 5 mils min average, 4 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Class 2 Circuits of Electronic Equipment of Appliances. |
|