Rating | 150 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 20 AWG - 500 kcmils, solid or stranded copper. |
|
Separator | Optional. |
|
Insulation | Extruded Silicone rubber. |
| Conductor size(AWG) | Minimum average thickness(mils) | Minimum thickness at any point(mils) |
| 20 - 12 | 30 | 27 |
| 11 - 8 | 45 | 40 |
| 7 - 2 | 60 | 54 |
| 1 - 3/0 | 80 | 76 |
| 4/0 - 500 | 95 | 85 |
|
Covering | Same as for Type SFF Fixture Wire. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Appliances. |
|