APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3536 Issued:1990-02-16
Revised:2014-04-23
Style 3536 Single conductor with extruded insulation.

Rating150 deg C, 600 Vac, Horizontal flame.
Conductor0.5 - 250 sq mm, solid or stranded.
InsulationExtruded Silicone rubber
Conductor size (sq mm)mils min averagemils min at any point
0.5-4.03027
4.1-9.04540
9.1-35.06054
35.1-100.08076
100.1-250.09585
May be applied in two layers with an intermediate glass braid (optional).
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances where totally enclosed.

UL and the UL Logo are trademarks of UL LLC © 2024