APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3550 Issued:1990-10-22
Revised:2012-05-08
Style 3550 Single Conductor with Extruded Insulation and Non-Extruded Covering

Rating200 deg C, 10000 Vac, Horizontal Flame.
Conductor22 AWG - 12 AWG, Solid or Stranded Round.
InsulationExtruded SR - Silicone, 40 mils minimum average, 36 mils minimum at any point.
CoveringNon-Extruded Fiberglass Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring for Rangetop Gas Appliance Ignition Systems where not exposed to moisture and where protected from damage during handling, installation and servicing of the appliance.