Rating | 150 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 32 AWG - 16 AWG solid or stranded, tinned, bare or plated. |
|
Insulation | Extruded XLFRPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. See facing page for compound designation. |
|
Shield | Optional. |
|
Covering | Optional - XLFRPE, 10 mils minimum average thickness, 8 mils mininum thickness at any point. Compound Designation same as insulation. |
|
Braid | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Appliances where not subjected to movement or mechanical damage. Tags may indicate the following: 600 V peak - for electronic use only. |
|