APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3566 Issued:1992-12-11
Revised:2012-04-02
Style 3566 Single Conductor with Extruded Insulation

Rating150 deg C, 600 Vac, Horizontal flame.
Conductor18 AWG - 4 AWG solid or stranded, coated. May employ rope lay construction.
InsulationExtruded SR - Silicone Rubber
AWG Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
18-94540
8-46055
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances where not subjected to flexing or motion.