Rating | 200 deg C, 600 Vac, Horizontal flame. |
|
Conductor | No. 18 AWG - 500 kcmil solid or stranded round. |
|
Insulation | Silicone rubber |
| 18-12 AWG conductor size | 30 mils min avg | 27 mils min at any point |
| 10 AWG | 45 avg | 40 min |
| 8-2 AWG | 60 avg | 54 min |
| 1-4/0 AWG | 80 avg | 72 min |
| 250-500 MCM | 95 avg | 85 min |
|
Braid | |
| For conductor sizes 18-2 AWG/MCM | 7.5 mils min avg |
| 1-3/0 AWM/MCM | 20 avg |
| 4/0-500 AWG/MCM | 30 avg |
|
Covering | Extruded FEP |
| For conductor sizes 18-2 AWG/MCM | 10 mils min avg | 8 mils min thickenss at any point |
| 1-3/0 AWM/MCM | 15 avg | 12 maap |
| 4/0-500 AWG/MCM | 20 avg | 16 maap |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Appliances in high temperature applications. |
|