APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3571 Issued:1993-11-05
Revised:2012-04-26
Style 3571 Multiple-conductor cable using non-integral jacket

Rating90 deg C, 600 Vac, Horizontal flame, Oil Resistant 60 deg C.
Conductor6 AWG - 250 kcmil solid or stranded round, tinned or bare copper.
InsulationEP
6-1 AWG conductor size45 mils min average40 mils minimum at any point
1/0-250 kcmil50 avg45 min
See facing page for compound designation.
JacketCPE
6-1 AWG conductor size40 mils min average32 mils minimum at any point
1/0-250 kcmil55 avg44 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances where exposed to temperatures not exceeding 90 deg. C and where exposed to oil at a temperature not exceeding 60 deg. C.

UL and the UL Logo are trademarks of UL LLC © 2024