APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3573 Issued:1994-03-17
Revised:2012-01-17
Style 3573 Insulated Wire

Rating200 deg C, 10000 Vac, Horizontal flame.
Conductor22 AWG - 12 AWG solid or stranded round.
InsulationSR - SILICONE, Inner insulation 30 mils min average, 27 mils minimum at any point. Outer insulation over braid - 10 mils min at any point.
BraidFiberglass braid or serve.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseElectronic Ignition or similar application in Gas Ranges or Gas or Fuel Oil Burner Systems where protected from damage during handling, installation and servicing of the appliance.
 