APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3574 Issued:1994-04-21
Revised:2011-10-14
Style 3574 Single conductor with extruded insulation.

Rating150 deg C, 600 Vac, 60 deg C Wet.
Conductor12 AWG stranded; consisting of 38 AWG or smaller strands.
InsulationExtruded Silicone Rubber, 30 mils minimum average thickness, 27 mils minimum at any point. See Facing Page for Compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInsulated Singles in a Multi-Conductor Cable where the acceptability of the combination has been determined by Underwriters Laboratories Inc.