Style 3625 Multiple-conductor cable using non-intergral jacket

Rating105 deg C, 10000 Vdc, Horizontal flame.
ConductorMinimum 0.0015 in diameter resistance wire applied spirally around a ferrite loaded fluoro rubber coated kevlar core.(Optional) Semiconductive coating of urethane on resistance wire.
InsulationXLPE, 15 mils min average, 13 mils minimum at any point.
CoveringXLPVC, average thickness 15 mils minimum at any point 13 mils. Semiconductive Covering - EEA (Ethylene Ethyl Acrylate), PE, XLPE or other Polyolefin group applied over conductor/core assembly. Thickness not specified.
JacketXLPVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.