APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3628 Issued:1999-08-11
Revised:2013-01-07
Style 3628 Single insulated conductor with non-integral jacket

Rating90 deg C, 600 Vac, 60 deg C Wet
Conductor50 AWG - 10 AWG nickel, copper alloy or copper, size varies dependent upon wattage demand.
InsulationExtruded solid XLPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldBare copper braid. Combination of strand size and number of strands such that braid is equivalent to 18 AWG.
CoveringExtruded Nylon, 3 mils minimum thickness.
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseResistance Wire for Heating Cable Units where not evaluated for flame and where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.