APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3632 Issued:1999-09-30
Revised:2012-03-13
Style 3632 Single Conductor with Extruded Insulation

Rating150 deg C, 600 Vac, Horizontal flame.
Conductor0.25 mm2 - 50 mm2, stranded, tinned or coated.
InsulationExtruded SR - Silicone Rubber
Conductor size mm2Minimum average thickness (mils)Minimum thickness at any point (mils)
0.25-1.001513
1.51816
2.5-6.002220
10-16.002926
25-353733
504540
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing into cables.

UL and the UL Logo are trademarks of UL LLC © 2024