APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3636 Issued:2000-02-24
Revised:2012-04-16
Style 3636 Single conductor with extruded insulation.

Rating250 deg C, 7500 Vac, Horizontal flame.
Conductor22 AWG - 12 AWG, solid or stranded.
InsulationExtruded SR, 40 mils min average, 37 mils minimum at any point. In two layers, with an intermediate glass braid. Either layer shall not be less than 15 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances where totally enclosed.

UL and the UL Logo are trademarks of UL LLC © 2025