APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3657 Issued:2000-11-03
Revised:2016-12-21
Style 3657 Single conductor with extruded insulation

Rating105 deg C, 600 or 1000 Vac, Horizontal flame.
Conductor50 AWG - 2000 kcmil, solid or stranded.
InsulationExtruded XLPO.
Conductor sizeMinimum average thicknessMinimum thickness at any point
50-10 AWG30 mils27 mils
9-8 AWG45 mils41 mils
7-2 AWG60 mils54 mils
1-4/0 AWG80 mils72 mils
250-500 kcmil95 mils86 mils
501-1000 kcmil110 mils99 mils
1001-2000 kcmil125 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024