APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3670 Issued:2001-09-18
Revised:2018-11-26
Style 3670 Single Conductor with Extruded Insulation

Rating105 deg C, 1500 Vac, Horizontal Flame.
Conductor0.40-95.0 mm sq. stranded, tinned or bare copper.
InsulationExtruded Silicone Rubber, See facing page for compound.
0.40-4.0 sq mm conductor size0.76 mm min average0.60 mm minimum at any point
4.5-6.0 sq mm1.00 avg.90 min
10.0-20.0 sq mm1.90 avg1.70 min
25.0-35.0 sq mm2.20 avg2.00 min
50.0-95.0 sq mm2.40 avg2.20 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial Test Probe Lead or Internal Wiring

UL and the UL Logo are trademarks of UL LLC © 2024