APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3684 Issued:2002-12-10
Revised:2012-11-30
Style 3684 Insulated Wire

Rating90 deg C, 600 Vac, FT2 flame.
Conductor30 AWG -2000 KCMIL solid or stranded.
InsulationExtruded EPDM
0.05-2.5 sq mm conductor size0.80 mm min average0.72 mm minimum at any point
4.0-6.0 sq mm1.10 avg1.00 min
10.0-16.0 sq mm1.20 avg1.08 min
25.0-35.0 sq mm1.40 avg1.26 min
50.0-70.0 sq mm1.60 avg1.44 min
95.0-120.0 sq mm1.80 avg1.62 min
150 sq mm2.00 avg1.80 min
185 sq mm2.20 avg1.98 min
240 sq mm2.40 avg2.16 min
300 sq mm2.60 avg2.34 min
400-500 sq mm2.80 avg2.52 min
630-1000 sq mm3.20 avg2.88 min
30-11 AWG32 avg29 min
9 AWG43 avg40 min
7-5 AWG48 avg42 min
3-2 AWG55 avg50 min
1/0-2/0 AWG63 avg57 min
3/0-250 kcmil71 avg64 min
300 kcmil79 avg71 min
350 kcmil87 avg78 min
450 kcmil95 avg85 min
600 kcmil102 avg92 min
800-1000 kcmil110 avg99 min
1250-2000 kcmil125 avg113 min
Misc.Tape - (Optional) PETP tape over conductor.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing into jacketed cables only.

UL and the UL Logo are trademarks of UL LLC © 2024