Rating | 105 deg C, 1000 Vac, Horizontal Flame. Optional - -25 deg C. |
|
Conductor | 24 AWG - 2000 kcmil, Solid or Stranded. |
|
Insulation | Extruded XLEVA |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 24 - 10 AWG (0.2 - 4.0 sq mm) | 30 mils (0.76 mm) | 27 mils (0.69 mm) |
| 9 - 2 AWG (6.0 - 25.0 sq mm) | 60 mils (1.52 mm) | 54 mils (1.37 mm) |
| 1 - 4/0 AWG (35.0 - 95.0 sq mm) | 80 mils (2.03 mm) | 72 mils (1.83 mm) |
| 250 - 500 kcmil (120 - 240 sq mm) | 95 mils (2.41 mm) | 86 mils (2.18 mm) |
| 501 - 1000 kcmil (300 - 500 sq mm) | 110 mils (2.79 mm) | 99 mils (2.51 mm) |
| 1001 - 2000 kcmil (630 - 1000 sq mm) | 125 mils (3.18 mm) | 112 mils (2.84 mm) |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances. |
|