Style 3686 Single Conductor with Extruded Insulation

Rating90 deg C, 3000 Vac, Horizontal flame. Optional -25 deg C
Conductor14 AWG - 2000 kcmil solid or stranded
InsulationComposite Insulation - Extruded EP Inner Layer with Extruded XLEVA Outer Layer
AWG SizeEP Inner Layer minimum average thickness (mils)EP Inner Layer minimum thickness at any point (mils)XLEVA Outer Layer minimum average thickness (mils)XLEVA Outer Layer minimum thickness at any point (mils)
14-1060543027
9-280724540
1-4/0105955550
250-500 kcmil1251136558
501-1000 kcmil1401268072
1001-2000 kcmil1551409586
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal Wiring