APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3687 Issued:2003-04-11
Revised:2011-07-28
Style 3687 Single Conductor with Extruded Insulation

Rating90 deg C, 150 Vac, Horizontal flame
Conductor32 AWG - 4 AWG stranded
InsulationExtruded XLFRPE or extruded XLPE
Conductor size AWGMinimum average thicknessMinimum thickness at any point
32-1912 mils10 mils
18-1615 mils13 mils
15-920 mils17 mils
8-230 mils27 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal Wiring of Appliances. Tags may indicate the following: 300 Volt Peak - For Electronic Use Only

UL and the UL Logo are trademarks of UL LLC © 2024