APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3736 Issued:2004-10-04
Revised:2012-03-31
Style 3736 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 9 AWG, solid or stranded
InsulationExtruded XLPE, 9 mils minimum average thickness, 8 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded XLPE, 8 mils minimum average thickness, 6 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances and Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024