APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3742 Issued:2004-11-17
Revised:2012-12-13
Style 3742 Single-conductor cable using non-integral jacket

Rating105 deg C, 600 Vac, Cable flame.
Conductor18 AWG - 4/0 AWG, stranded. A fibrous thread may be used within the conductor stranding.
InsulationExtruded EP.
Conductor sizeMinimum average thicknessMinimum thickness at any point
18-10 AWG30 mils27 mils
9-8 AWG45 mils40 mils
7-2 AWG60 mils54 mils
1-4/0 AWG80 mils72 mils
ShieldOptional.
JacketPVC, 60 mils min average, 48 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external wiring of Appliances or Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024