APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3750 Issued:2005-02-04
Revised:2012-04-04
Style 3750 Single conductor with extruded insulation.

Rating150 deg C, 4000 Vac, Horizontal flame.
Conductor30 AWG - 10 AWG, solid or stranded.
InsulationExtruded SR, 15 mils min average, 13 mils minimum at any point.
CoveringOptional. Extruded SR, 10 mils minimum average, 8 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances where totally enclosed, or not subjected to movement or mechanical abuse.