APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3761 Issued:2005-07-01
Revised:2011-09-02
Style 3761 Single conductor with extruded insulation.

Rating150 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 46 AWG resistance wire coiled around a fiberglass yarn core. One or more straight wires may be placed under the turns of the resistance wire. May have helically wound or braided glass fiber separator over the coiled resistance wire.
InsulationExtruded SR, 24 mils minimum average, 21 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subjected to movement after installation.

UL and the UL Logo are trademarks of UL LLC © 2024