Rating | 90 deg C, 1000 Vac. |
|
Conductor | 30 AWG - 2000 kcmil, solid or stranded. |
|
Separator | Optional, PETP tape over conductor. |
|
Insulation | Extruded EPDM |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 30-11 AWG | 32 mils | 29 mils |
| 9 AWG | 43 mils | 40 mils |
| 7-5 AWG | 48 mils | 42 mils |
| 3-2 AWG | 55 mils | 50 mils |
| 1/0-2/0 AWG | 63 mils | 57 mils |
| 3/0-250 kcmil | 71 mils | 64 mils |
| 300 kcmil | 79 mils | 71 mils |
| 350 kcmil | 87 mils | 78 mils |
| 450 kcmil | 95 mils | 85 mils |
| 600 kcmil | 102 mils | 92 mils |
| 800-1000 kcmil | 110 mils | 99 mils |
| 1250-2000 kcmil | 125 mils | 113 mils |
| 0.05-2.5 sq mm | 0.80 mm | 0.72 mm |
| 4.0-6.0 sq mm | 1.10 mm | 1.00 mm |
| 25.0-35.0 sq mm | 1.40 mm | 1.26 mm |
| 50.0-70.0 sq mm | 1.60 mm | 1.44 mm |
| 95.0-120.0 sq mm | 1.80 mm | 1.62 mm |
| 150 sq mm | 2.00 mm | 1.80 mm |
| 185 sq mm | 2.20 mm | 1.98 mm |
| 240 sq mm | 2.40 mm | 2.16 mm |
| 300 sq mm | 2.60 mm | 2.34 mm |
| 400-500 sq mm | 2.80 mm | 2.52 mm |
| 630-1000 sq mm | 3.20 mm | 2.88 mm |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For further processing into jacketed cables only. |
|