APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3808 Issued:2007-07-11
Revised:2011-11-04
Style 3808 Single conductor with extruded insulation

Rating230 deg C, 300 Vac, Horizontal flame.
ConductorNo. 30-16 AWG, solid or stranded
InsulationExtruded Silicone rubber, Two layers totaling Nominal 30 mils of Silicone rubber, each layer is 15 mils minimum average thickness and 13 mils minimum at any point; between the layers an intermediate glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where totally enclosed.