Rating | 90 deg C, 600 V, Horizontal Flame, 60 deg C Oil. |
|
Conductor | 24 - 4 AWG. |
|
Insulation | Extruded Thermoset CPE |
| Conductor Size | Minimum average thickness | Minimum thickness at any point |
| 24-10 AWG | 31 mils | 27 mils |
| 9-8 AWG | 45 mils | 41 mils |
| 7-4 AWG | 60 mils | 54 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|