APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3842 Issued:2009-07-23
Revised:2011-07-28
Style 3842 Single Conductor with Extruded Insulation and Non-integral Extruded Jacket.

Rating90 deg C, 1000 Vac Cable flame, Optional - 60 deg C Oil
Conductor30 AWG - 2000 kcmil, solid or stranded
InsulationExtruded EPDM, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldOptional
CoveringOptional - non-extruded - 1 mil or heavier PET, PETP tape may be applied over the conductor assembly.
JacketExtruded CP or CPE
Diameter (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.000-0.7003326
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseExternal interconnection

UL and the UL Logo are trademarks of UL LLC © 2024