APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3847 Issued:2009-08-07
Revised:2012-07-28
Style 3847 Single conductor with extruded insulation and non-integral jacket

Rating105 deg C, 1000 V ac Horizontal flame.
Conductor32 AWG - 10 AWG min. solid or stranded.
InsulationExtruded XLPE, 11 mils minimum average, 10 mils minimum at any point.
JacketExtruded XLPE, 10 mils minimum average, 8 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.