APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3941 Issued:2013-08-19
Revised:2013-08-20
Style 3941 Single-conductor cable using non-integral jacket

Rating90 deg C, 300 Vac, Horizontal flame.
Conductor44 AWG min., solid or stranded.
InsulationExtruded Foamed XLPE, 18 mils minimum average thickness, 16 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024