Rating | 150 deg C,1000 Vdc Horizontal flame. |
|
Conductor | 30 AWG - 4/0 AWG, solid or stranded. |
|
Insulation | Extruded XLPE |
| AWG Conductor Size | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 30-9 | 30 | 27 |
| 8-4 | 45 | 40 |
| 2 | 60 | 54 |
| 1-4/0 | 80 | 72 |
|
Covering | Optional, treated or untreated braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of appliances. |
|