APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3971 Issued:2014-10-29
Revised:New
Style 3971 Single conductor with extruded insulation

Rating150 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 2 AWG, stranded.
InsulationExtruded SR (Silicone Rubber)
Conductor sizeMinimum average thicknessMinimum thickness at any point
26-10 AWG30 mils27 mils
9-7 AWG40 mils36 mils
6-2 AWG60 mils54 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.