APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4002 Issued:1959-05-01
Revised:2012-07-18
Style 4002 Four-Conductor Type SV Cord.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor20 AWG consisting of No. 34 or 36 AWG stranded.
InsulationExtruded CP, CPE, EP, NBR/PVC, NR - NEOPRENE, SRB/NR, XL, 15 mils min average, 14 mils minimum at any point. Cotton Braid shall be provided over the individual insulated conductors. Conductors shall be twisted with a maximum lay of 2 inches.
AssemblyFour conductor, same as type SV. Cotton Braid shall be provided over the individual insulated conductors. Conductors shall be twisted with a maximum lay of 2 inches.
JacketExtruded CP, EPDM, NBR/PVC, NR - NEOPRENE, SRB/NR, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only on Television Receivers.

UL and the UL Logo are trademarks of UL LLC © 2024