APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4016 Issued:1959-05-01
Revised:2011-10-14
Style 4016 Two-Conductor Type SP-2 Cord.

Rating90 deg C, 300 Vac, FT2 flame, 60 deg C Oil.
Conductor20 AWG - 16 AWG consisting of No. 30 AWG or smaller copper strands.
InsulationIntegral with Jacket. Extruded Neoprene, 45 mils minimum average thickness, 40 mils minimum at any point.
AssemblyTwo conductors, same as type SP-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only in Internal Wiring of Lighting Circuits in Refrigerating Equipment. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024