APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4022 Issued:1959-05-01
Revised:2012-07-07
Style 4022 Parallel cable with extruded integral insulation and jacket.

Rating75 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded.
InsulationExtruded Integral SRB/NR insulation and jacket, 60 mils min average, 54 mils minimum at any point.
AssemblyTwo conductor, same as type SP-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only in Internal Wiring of Electric Refrigerators or Gas or Oil-Fired Domestic Heating Equipment where exposed to temperatures not exceeding 75 deg C. Polarity identification may be omitted.