Rating | 90 deg C, 600 Vac, FT2 flame, Oil Resistant 60 deg C (optional). |
|
Conductor | 18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded. |
|
Integral | Extruded NR - NEOPRENE, 60 mils min average, 54 mils minimum at any point. |
|
Assembly | Two conductor, Same as for Type SP Cord except with a nominal 60 mils wall or See Facing Page, and the following (Pin Gauge) dimensions: Wall thickness: 0.058 in, Web thickness: 0.078 in, Wall after rip: 0.028 in. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electric Refrigerators or other equipment where ripped not more than 3 in unless installed in a separate metal enclosure; or for use only in the wiring of butter conditioners where exposed at the door hinge. Additional Ratings: A) Where exposed to oil at a temperature not exceeding 60 deg C. B) "125 deg C in air". See Facing Page for Compound. |
|