APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4035 Issued:1959-05-01
Revised:2012-04-24
Style 4035 Parallel cable with extruded integral insulation and jacket.

Rating75 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded.
InsulationIntegral with Jacket. Extruded NEOPRENE, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
AssemblyThree conductor, same as type SP with a nominal 60 mils wall the following (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators where ripped not more than three inches unless installed in a separate metal enclosure; or for use only in the wiring of butter conditioners where exposed at the door hinge. Both uses may add: and where exposed to temperatures not exceeding 75 deg C, and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.