Rating | 75 deg C, 300 Vac, FT2 flame. |
|
Conductor | 18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded. |
|
Insulation | Integral with Jacket. Extruded NEOPRENE, 60 mils minimum average thickness, 54 mils minimum thickness at any point. |
|
Assembly | Three conductor, same as type SP with a nominal 60 mils wall the following (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electric Refrigerators where ripped not more than three inches unless installed in a separate metal enclosure; or for use only in the wiring of butter conditioners where exposed at the door hinge. Both uses may add: and where exposed to temperatures not exceeding 75 deg C, and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted. |
|