Rating | 90 deg C, 600 Vac, Horizontal flame. Optional - Oil Resistant 60 deg C |
|
Conductor | 18 AWG - 16 AWG, solid or consisting of No. 30 AWG or smaller strands |
|
Insulation | Extruded Neoprene, 60 mils minimum average thickness, 54 mils minimum thickness at any point |
|
Assembly | Three conductor, same as Type SP with the following (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electric Refrigerators where ripped not more than 3 in unless in-stalled in a separate metal enclosure; or for use only in the wiring of butter conditioners where exposed at the door hinge. Additional Ratings: A) "125 deg C in air", see Facing Page for Compound. |
|