APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4036 Issued:1959-05-01
Revised:2012-02-16
Style 4036 Parallel cable with extruded integral insulation and jacket

Rating90 deg C, 600 Vac, Horizontal flame. Optional - Oil Resistant 60 deg C
Conductor18 AWG - 16 AWG, solid or consisting of No. 30 AWG or smaller strands
InsulationExtruded Neoprene, 60 mils minimum average thickness, 54 mils minimum thickness at any point
AssemblyThree conductor, same as Type SP with the following (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators where ripped not more than 3 in unless in-stalled in a separate metal enclosure; or for use only in the wiring of butter conditioners where exposed at the door hinge. Additional Ratings: A) "125 deg C in air", see Facing Page for Compound.

UL and the UL Logo are trademarks of UL LLC © 2024