APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4038 Issued:1959-05-01
Revised:2012-05-04
Style 4038 Parallel Cable with Extruded Integral Insulation and Jacket

Rating75 deg C, 300 Vac, Horizontal flame.
Conductor14 AWG - 10 AWG consisting of No. 30 AWG or smaller solid or stranded round, tinned or bare.
InsulationExtruded NR - integral with Jacket, 80 mils minimum average thickness, 72 mils minimum thickness at any point.
AssemblyTwo conductor, same as type SP Cord with a nominal 60 mils wall tickness and the following (pin gauge) dimensions:
Wall thickness:70 mils
Web thickness:109 mils
Wall after rip:43 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Room Cooler Units where ripped not more than three inches, unless installed in a separate metal enclosure. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024