APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4039 Issued:1959-05-01
Revised:2012-02-10
Style 4039 Parallel Cable with Extruded Integral Insulation.

Rating75 deg C, 300 Vac, Horizontal flame, 60 deg C Oil.
Conductor14 AWG - 10 AWG, consisting of 30 AWG or smaller strands.
InsulationExtruded Neoprene, 80 mils minimum average thickness, 70 mils minimum thickness at any point before rip, 43 mils minimum thickness at any point after rip, 109mils minimum web thickness.
AssemblyTwo conductor, similar to Type SP.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Room Cooler Units where ripped not more than three inches unless installed in a separate metal enclosure and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024